Pile Foundation Design for a 9-Story Office Building (Case Study: Mozia Office, South Tangerang)
DOI:
https://doi.org/10.56127/jts.v5i1.2656Keywords:
pile foundation, foundation bearing capacity, SPT, pile group efficiency, foundation settlementAbstract
Building safety is largely determined by the ability of the foundation to transfer structural loads to soil layers with adequate bearing capacity. Therefore, in conditions where the surface soil is weak, pile foundations are used to reach more stable layers. This study evaluates the performance of pile foundations at the Mozia Office Building, a nine-storey office building in Bumi Serpong Damai, through an analysis of bearing capacity, group efficiency, and foundation settlement based on SPT data and laboratory testing with parameters of N-SPT, soil weight, porosity, and soil shear strength. The foundation capacity was calculated by separating the end bearing capacity using the Meyerhof method and the skin friction using the α method according to McClelland (1974) and Reese and Wright (1977), while the pile group efficiency was reviewed conservatively from several empirical methods and the settlement was analysed using semi-empirical methods and Vesic (1977). The analysis results indicate that the effective soil layer for pile tip placement is at a depth of approximately 10 m, with an ultimate bearing capacity of 9,153.55 kN, a permissible bearing capacity of 3,051.18 kN, and a single pile settlement of 4.43 cm and a pile group settlement of 6.27 cm, which still meet the permissible limits. Therefore, the planned pile foundation is considered safe and suitable for use.
References
"BSN, Standar Nasional Indonesia Persyaratan perancangan geoteknik. (2017). www.bsn.go.id
Abidin, S., Novianto, D., & Asukmajaya, B. (2022). Analisis Ulang Perencanaan Pondasi Tiang Pancang Zona 8 Proyek Stadion Internasional Jakarta (Vol. 3, Number 2). http://jos-mrk.polinema.ac.id/
Aisah, E. (n.d.). Analisis Kapasitas Daya Dukung Pondasi Tiang Pancang Dengan Metode Us.Army Corps.
Eltris Don, M., Supryadi, G., Cempang, C., Haza3, Z. F., Darmawan, A., Studi, P., & Sipil, T. (n.d.). Analysis Perbandingan Pondasi Tiang Bore Pile Dan Pondasi Tiang Pancang Pada Gedung 5 Lantai Menggunakan Data N-Spt. In Tekla) (Vol. 6, Number 2).
Indah Sari, K. (n.d.). Analisa Daya Dukung Pondasi Tiang Pancang Beton Pada Proyek Pembangunan Rumah Sakit Di Kabupaten Deli Serdang. In Jtsip (Vol. 1, Number 1).
Mardianti, I. Y., Nuklirullah, M., & Dwina, D. O. (2022). Analisis Daya Dukung Pondasi Tiang Pancang Berdasarkan Data Sondir (Studi Kasus : Pembangunan Gedung Rumah Sakit Pendidikan Universitas Jambi). In Menara : Jurnal Teknik Sipil (Vol. 17, Number 2).
Oemar, F., & Kamil Y, A. G. (n.d.). Analisa Daya Dukung Pondasi Tiang Pancang Pada Proyek Pembangunan Gedung Arsip Dinas Bina Marga Provinsi Dki.
Ramadhan, M. A., Aji, G., Sophian, I., & Yan, T. (n.d.). Analisis Daya Dukung Tanah Pondasi Tiang Pancang Berdasarkan Uji Spt Di Ibu Kota Negara (Ikn), Kalimantan Timur, Indonesia.
Suci Abadi, S., & Permana, S. (n.d.). Analisis Perbandingan Kapasitas Kuat Dukung Pondasi Bore Pile Berdasarkan Hasil Pengujian SPT dan CPT. Retrieved https://jurnal.itg.ac.id/
Tanjung, D. K., & Zaki, M. (2025). Analisis Tiang Pancang dengan Uji Dinamis dan Statis terhadap Kapasitas Ijin Manufaktur. In Journal of Comprehensive Science (Vol. 4, Number 1).